Cause 1
Incoming Power Problem
The central air condensing unit is energized with 240 volts of electricity. This electricity then flows through the disconnect box to the compressor and condenser fan motor. The disconnect box enables the air conditioning unit to be turned off outside. The disconnect boxes includes a cartridge which may contain fuses. If the compressor and condenser fan motor do not run, the disconnect box fuses may have blown, or the circuit breaker supply power to the disconnect box may have tripped. To determine if the disconnect box fuses have blown, use a multimeter to test the fuses for continuity. If the disconnect box fuses do not have continuity, replace the disconnect box.
Cause 2
Dual Run Capacitor
If the dual run capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the dual run capacitor has failed, inspect the capacitor. If the dual run capacitor is bulging or leaking, replace it.
Cause 3
Contactor
The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. To determine if the contactor is at fault, use a multimeter to test the contactor for continuity. If the contactor does not have continuity, replace it.